 DC-DC Converter UNIT
1R Serie ( 1W SINGLE OUTPUTS WITH REGULATION )
FEATURES
1000VDC ISOLATION HIGH EFFICIENCY INTERNAL FILTERING LOW COST NO EXTERNAL COMPONENTS REQUIRED UP TO 1W REGULATED OUTPUT POWER SINGLE IN LINE PACKAGE 100% BURNED IN LOW NOISE MTBF > 800,000 HOURS
OUTPUT SPECIFICATIONS
Voltage Set point Accuracy Temperature Coefficient Ripple & Noise (20MHz BW) Line Regulation1 Load Regulation
2
INPUT SPECIFICATIONS
+/-2% max Input Voltage Range +/-0.03%/ OC Input Filter 100mVp-p max +/-0.5% max +/-0.5% max +/-10% max Capacitor Type
GENERAL SPECIFICATIONS
60% min
3
Short Circuit Protection Short Circuit Restart
Current Limit Protection Efficiency Automatic Isolation Voltage
1000 VDC min 9 10 ohms min 50 KHz min 80pF max 800,000 Hours 7.0g Typ Non-Conductive Plastic 31.8mm*8.6mm*14.5mm
ENVIRONMENTAL SPECIFICATIONS
Operating Temperature Storage Temperature Cooling
Isolation Resistance
-25 OC to +71 OC Switching Frequency -55 OC to +125 OC Isolation Capacitance Free-Air Convection MTBF Weight
ALL SPECIFICATIONS TYPICAL AT NOMINAL LINE, FULL LOAD , AND 25 OC UNLESS OTHERWISE NOTED.
Case Material Case Size
1 2 3
High Line to Low Line. Load Regulation is for output load current change from 10% to 100%. For 60 seconds
www.Power-Systems.de
Page: 1 / 5
Version: 4-Oct-02
DC-DC Converter UNIT
1R Serie ( 1W SINGLE OUTPUTS WITH REGULATION )
SELECTION GUIDE 1W OUTPUT
MODEL NUMBER INPUT (VDC)
4.5-5.5 4.5-5.5 4.5-5.5 4.5-5.5 4.5-5.5 4.5-5.5 4.5-5.5 10.8-13.2 10.8-13.2 10.8-13.2 10.8-13.2 10.8-13.2 10.8-13.2 10.8-13.2 21.6-26.4 21.6-26.4 21.6-26.4 21.6-26.4 21.6-26.4 21.6-26.4 21.6-26.4
OUTPUT (VDC)
5 9 12 15 +/-5 +/-12 +/-15 5 9 12 15 +/-5 +/-12 +/-15 5 9 12 15 +/-5 +/-12 +/-15
OUTPUT (mA)
200 111 84 67 +/-100 +/-42 +/-34 200 111 84 67 +/-100 +/-42 +/-34 200 111 84 67 +/-100 +/-42 +/-34
INPUT CURRENT(mA)
FULL LOAD NO LOAD 23 22 22 21 23 22 21 15 15 15 15 15 15 15 7 6 6 6 7 6 6 62 60 62 62 62 62 62 67 62 64 63 67 64 63 68 65 70 70 68 70 70 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000
VOLTAGE VOLTAGE CURRENT
EFF (%)
ISOLATION (VDC)
1RS-0505 1RS-0509 1RS-0512 1RS-0515 1RD-0505 1RD-0512 1RD-0515 1RS-1205 1RS-1209 1RS-1212 1RS-1215 1RD-1205 1RD-1212 1RD-1215 1RS-2405 1RS-2409 1RS-2412 1RS-2415 1RD-2405 1RD-2412 1RD-2415
322 333 322 322 322 322 322 124 134 130 132 124 130 132 61 64 60 60 61 60 60
Note: Other input to output voltages may be available. Please contact factory.
www.Power-Systems.de
Page: 2 / 5
Version: 4-Oct-02
DC-DC Converter UNIT
1R Serie ( 1W SINGLE OUTPUTS WITH REGULATION )
SIMPLIFIED SCHEMATIC
SINGLE OUTPUT
+Vin
OSCILLATOR DRIVER REGULATOR
DUAL OUTPUT
+Vout
+Vin
OSCILLATOR DRIVER REGULATOR
+Vout Com. -Vout
-Vin
-Vout
-Vin
REGULATOR
MECHANICAL DIMENSIONS & RECOMMENDED FOOTPRINT DETAILS
PIN 1 2 3 9 10 11 12
SINGLE +Vin NC NC NC -Vout +Vout -Vin
DUAL +Vin -Vout NC NC Common +Vout -Vin
www.Power-Systems.de
Page: 3 / 5
Version: 4-Oct-02
DC-DC Converter UNIT
1R Serie ( 1W SINGLE OUTPUTS WITH REGULATION )
TYPICAL APPLICATIONS
SINGLE OUTPUT
INPUT
+Vin +Vout
DUAL OUTPUT
INPUT
+Vin +Vout
OUTPUT
OUTPUT
LOAD1
DC-DC CONVERTER
-Vin -Vout
LOAD
DC-DC CONVERTER
-Vin
Common
LOAD2
-Vout
TYPICAL PERFORMANCE CUREVES
Specifications typical at ta=25 OC,nominal input voltage , rated output current unless otherwise specified.
OUTPUT LOAD vs EFFICIENCY
100% EFFICIENCY(%) 80% 60% 40% 20% 0% 0% OUTPUT VOLTAGE CHANGE(%) 80% 100%
OUTPUT LOAD vs OUTPUT VOLTAGE
10% 5% 0% -5% -10% 0%
SAFE OPERATING AREA
20% 40% 60%
20%
40%
60%
80%
100%
OUTPUT LOAD(%)
OUTPUT LOAD(%)
TEMPERATURE DERATING
1.2 OUTPUT POWER(W) 0.9 0.6 0.3 0.0 -25 0 25 50 70 100 TA(degree C)
EFFICIENCY(%) 100% 80% 60% 40% 20%
INPUT VOLTAGE vs EFFICIENCY
0% -10
-5
Nom
5
10
INPUT VOLTAGE(%)
www.Power-Systems.de
Page: 4 / 5
Version: 4-Oct-02
DC-DC Converter UNIT
1R Serie ( 1W SINGLE OUTPUTS WITH REGULATION )
1R SERIES APPLICATION NOTES:
EXTERNAL CAPACITANCE REQUIREMENTS:
No external capacitance is required for operation of the 1R series. To meet the reflected ripple requirements of the converter, an input impedance of less than 0.5 ohm from DC to 100KHz is required. External output capacitance is not required for operation, however it is recommended that 10uF tantalum and 0.1uF ceramic capacitance be selected for reduced system noise. Additional output capacitance may be added for increased filtering, but should not exceed 220uF.
Negative Outputs:
A negative output voltage may be obtained by connecting the +OUT to circuit ground and connecting -OUT as the negative output.
FOR MORE INFORMATION CALL: Power Systems - The Power Solution
74360 Ilsfeld-Auenstein ( Germany ) Dornet 8 E-mail: Info@Power-Systems.de Tel: + 49 / 70 62 / 67 59 - 6 Fax: + 49 / 70 62 / 67 59 -80
Home Page: www.Power-Systems.de
www.Power-Systems.de
Page: 5 / 5
Version: 4-Oct-02


▲Up To Search▲   

 
Price & Availability of 1RD-2405

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X